TNT Filter Services
TNT Filter Services
Wadgaon Sheri, Pune, Maharashtra
GST No. 27ATHPD5275A2ZY
Send E-mail
Call 0794278717581% Response Rate

Tap Changer Parts


Pioneers in the industry, we offer epoxy arm for tap changer, oltc fixed contact, tap changer main moving contact, olg make oil seal assembly and oil surge relay for oltc/transformer from India.

REQUEST CALLBACK
Get Best Quote

Approx. 2,999 / Piece Get Latest Price

View Brochure
Service Details:
Minimum Order Quantity1 Piece
Usage/ApplicationTap Changer Parts
Transformer TypePower Transformer
PhaseThree Phase
BrandTNT
Country of OriginMade in India

Tap changers exist in two primary types, no-load tap changers (NLTC), which must be de-energized before the turn ratio is adjusted, and on-load tap changers (OLTC), which may adjust their turn ratio during operation. The tap selection on any tap changer may be made via an automatic system, as is often the case for OLTC, or a manual tap changer, which is more common for NLTC. Automatic tap changers can be placed on a lower or higher voltage winding, but for high-power generation and transmission applications, automatic tap changers are often placed on the higher voltage (lower current) transformer winding for easy access and to minimize the current load during operation.

Additional Information:
  • Item Code: TNT07
  • Production Capacity: 500
  • Delivery Time: Immediate

Yes! I am interested


REQUEST CALLBACK
  • +7
Get Best Quote

Approx. 1,200 / Piece Get Latest Price

View Brochure
Service Details:
Minimum Order Quantity1 Piece
Power2000 kVA
MaterialCopper
Cooling TypeOil Cooled
Insulation ClassA
Country of OriginMade in India

Fixed Contact Use For Tap Changer (OLTC)

tap changer is a mechanism in transformers which allows for variable turn ratios to be selected in distinct steps. This is done by connecting to a number of access points known as taps along either the primary or secondary winding.

Tap changers exist in two primary types,[1] no-load tap changers (NLTC), which must be de-energized before the turn ratio is adjusted, and on-load tap changers (OLTC), which may adjust their turn ratio during operation. The tap selection on any tap changer may be made via an automatic system, as is often the case for OLTC, or a manual tap changer, which is more common for NLTC. Automatic tap changers can be placed on a lower or higher voltage winding, but for high-power generation and transmission applications, automatic tap changers are often placed on the higher voltage (lower current) transformer winding for easy access and to minimize the current load during operation



Additional Information:
  • Production Capacity: 1000

Yes! I am interested


  • +2
Get Best Quote

Approx. 6,999 / Piece Get Latest Price

View Brochure
Service Details:
Minimum Order Quantity1 Piece
Usage/ApplicationTap Changer (OLTC)
Transformer TypePower Transformer
PhaseThree Phase
ShapeSquare
Country of OriginMade in India

On Load Gears is pleased to offer all its clients the MOST competitive Annual Maintenance Contract (AMC) in the market. Being a pioneer in the business of OLTC manufacturing OLG has been able to analyze the major problems and service related issues that occur in not only their products but also products manufactured by others in the same field. It is through this experience and fact-finding approach that OLG has been able to devise a very attractive and competitive AMC.

Additional Information:
  • Item Code: TNT03
  • Production Capacity: 1000
  • Delivery Time: Immediately

Yes! I am interested


REQUEST CALLBACK
Get Best Quote

Approx. 7,000 / Piece Get Latest Price

Service Details:
Minimum Order Quantity1 Piece
TypeOn Load Tap Changer
Transformer TypePower Transformer
PhaseThree Phase
BrandTNT
Country of OriginMade in India

OLG Oil Seal Housing Assembly

tap changer is a mechanism in transformers which allows for variable turn ratios to be selected in distinct steps. This is done by connecting to a number of access points known as taps along either the primary or secondary winding.

Tap changers exist in two primary types,[1] no-load tap changers (NLTC), which must be de-energized before the turn ratio is adjusted, and on-load tap changers (OLTC), which may adjust their turn ratio during operation. The tap selection on any tap changer may be made via an automatic system, as is often the case for OLTC, or a manual tap changer, which is more common for NLTC. Automatic tap changers can be placed on a lower or higher voltage winding, but for high-power generation and transmission applications, automatic tap changers are often placed on the higher voltage (lower current) transformer winding for easy access and to minimize the current load during operation



Additional Information:
  • Production Capacity: 10 nos

Yes! I am interested


Get Best Quote

Approx. 4,555 / PIECE Get Latest Price

View Brochure
Service Details:
Minimum Order Quantity1 PIECE
Number Of Poles2 Pole
Usage/ApplicationTransformer And OLTC
Transformer TypePower Transformer
PhaseThree Phase
TypeCurrent Relay
Voltage220V
MaterialMild Steel

OSR And PRV Switch For Transformer And OLTC

Additional Information:
  • Item Code: TNT12
  • Production Capacity: 100
  • Delivery Time: Immediate

Yes! I am interested


 

 

 

Send SMS
Bhagyashree  (Manager)
TNT Filter Services
S No 35/1, Sai Krupa Society, Wadgoansheri, Pune, Pune, Maharashtra,
Wadgaon Sheri, Pune - 411014 , Maharashtra , India
Send E-mail
Share Us:
X